Model |
|
Tempra™ 12 |
Tempra™ 15 |
Tempra™ 20 |
Tempra™ 24 |
Tempra™ 29 |
Tempra ™ 36 |
Phase |
|
1 |
1 |
1 |
1 |
1 |
1 |
Voltage |
V |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
Wattage |
kW |
9 |
12 |
10.8 |
14.4 |
14.4 |
19.2 |
18 |
24 |
21.6 |
28.8 |
27 |
36 |
Amperage |
A |
44 |
50 |
52 |
60 |
70 |
80 |
88 |
100 |
105 |
120 |
132 |
150 |
Min. required circuit breaker size |
A |
60 |
60 |
2 x 40 |
2 x 40 |
2 x 50 |
2 x 50 |
2 x 60 |
2 x 60 |
3 x 50 |
3 x 50 |
3 x 60 |
3 x 60 |
Recommended wire size |
AWG COPPER |
6 |
6 |
2 x 8 |
2 x 8 |
2 x 8 |
2 x 8 |
2 x 6 |
2 x 6 |
3 x 8 |
3 x 8 |
3 x 6 |
3 x 6 |
Maximum temp. increase |
@1.50 GPM |
41 |
54 |
49 |
65 |
66 |
88 |
82 |
92 |
92 |
92 |
92 |
92 |
above ambient water temp. |
@2.25 GPM |
27 |
36 |
37 |
43 |
44 |
58 |
54 |
73 |
66 |
87 |
82 |
92 |
|
@3.00 GPM |
20 |
27 |
25 |
33 |
33 |
44 |
41 |
54 |
49 |
66 |
61 |
82 |
| |
@4.50 GPM |
- |
- |
- |
- |
22 |
29 |
27 |
37 |
33 |
44 |
41 |
55 |
Min. water flow to activate unit |
GPM / Lmin |
0.29 / 1.1 |
0.58 / 2.2
|
0.58 / 2.2 |
0.58 / 2.2 |
0.87 / 3.3 |
0.87 / 3.3 |
Weight |
Lb / Kg |
15 / 6.8 |
18 / 8.1 |
21 / 9.5 |
18 / 8.1 |
24.25 / 11 |
24.25 / 11 |
Nominal water volume |
Gal / L |
0.13 / 0.5 |
0.26 / 1.0 |
0.26 / 1.0 |
0.26 / 1.0 |
0.39 / 1.5 |
0.39 / 1.5 |
Width |
inch / cm |
14 9/16 / 37
|
21 3/4 / 55.2 |
21 3/4 / 55.2 |
Height |
inch / cm |
|
Depth |
inch / cm |
4 5/8 / 11.6 |
Working pressure |
PSI / BAR |
150 / 10 |
Tested to pressure |
PSI / BAR |
300 / 20 |
Water connections |
|
3 / 4" NPT |
Temperature Increase above Water Temperature: